GT Series Archives - Aiphone https://www.aiphone.com/kbtopic/gt-series/ World Leader in Intercoms and Access Control Thu, 10 Apr 2025 18:34:54 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.2 GT-BC Technical Specification https://www.aiphone.com/kb/gt-bc-technical-specification/ Thu, 18 Nov 2021 03:00:33 +0000 https://aiphone.local/kb/gt-bc-technical-specification/ Line Drawing Specifications Power Source 24V DC, supplied from PS-2420UL Power Consumption Max. 0.9A Capacity Maximum 48 tenant stations per (25 per trunk) Wire 2-conductor 18AWG, PE insulation Wiring Distance GT-BC to furthest tenant station: 980′ GT-BC to PS-2420UL: 33′ Mounting Surface wall mount or DIN rail (W-DIN11) Operating Temperature 0~40℃(32~104°F) Dimensions 4-¼” H x […]

The post GT-BC Technical Specification appeared first on Aiphone.

]]>
Line Drawing

Specifications

Power Source

24V DC, supplied from PS-2420UL

Power Consumption

Max. 0.9A

Capacity

Maximum 48 tenant stations per (25 per trunk)

Wire

2-conductor 18AWG, PE insulation

Wiring Distance

GT-BC to furthest tenant station: 980′

GT-BC to PS-2420UL: 33′

Distances are calculated using 20AWG or 18AWG wire.

Mounting

Surface wall mount or DIN rail (W-DIN11)

Operating Temperature

0~40℃(32~104°F)

Dimensions

4-¼” H x 4-¹³⁄₁₆” W x 2-⅜” D

Weight

Approx. 0.99 lbs (450g)

The post GT-BC Technical Specification appeared first on Aiphone.

]]>
GT-DMB-N Technical Specifications https://www.aiphone.com/kb/gt-dmb-n-spec-sheet/ Sun, 15 Aug 2021 03:50:44 +0000 https://aiphone.local/kb/gt-dmb-n-spec-sheet/ Line Drawing Specifications Power Source 24V DC, use specified number of PS-2420ULs per system configuration Communication Hands-free Capacity Max. 16 entrance stations per system Max. 4 video guard stations per system Max. 500 tenant stations per system Max. 4 tenant stations per unit Wire Two sets of 2-conductor, PE insulation (two common buses for audio […]

The post GT-DMB-N Technical Specifications appeared first on Aiphone.

]]>
Line Drawing

Specifications

Power Source

24V DC, use specified number of PS-2420ULs per system configuration

Communication

Hands-free

Capacity

Max. 16 entrance stations per system
Max. 4 video guard stations per system
Max. 500 tenant stations per system
Max. 4 tenant stations per unit

Wire

Two sets of 2-conductor, PE insulation (two common buses for audio and video)

  • Aiphone #872002, 2-conductor PE insulated, non-shielded, 20AWG (audio)
  • Aiphone #871802, 2-conductor PE insulated, non-shielded, 18AWG (video)

Wiring Distance

GT-BC to farthest entrance station: 980′
GT-BC to farthest tenant station: 980′
GT-VBC to farthest entrance station: 980′
GT-VBC to farthest tenant station: 500′

Mounting

Flush-mount: Use GF-3B back box

Surface-mount: Use SBX-GTDMB surface-mount box

Operating Temperature

-22° ~ 140°F (-30° ~ 60°C)

Dimensions

12-⅝” H x 5-⅞” W

Weight

Approx. 2.64 lbs (1.2kg)

The post GT-DMB-N Technical Specifications appeared first on Aiphone.

]]>
GT-MCX Technical Specifications https://www.aiphone.com/kb/gt-mcx/ Sun, 15 Aug 2021 04:02:45 +0000 https://aiphone.local/kb/gt-mcx/ Line Drawing Specifications Power Source 24V DC, PS-2420UL Standby 75mA, Maximum 125mA Wire 2-conductor, PE insulation CAT5e/6 Wiring Distance GT-MCX to power supply: 16′ GT-MCX to distribution point: 165′ GT-MCX to GT-VBC 165′ GT-MCX to GT-BC: 165′ GT-MCX to network switch: 330′ Protocol IPv4, IPv6, TCP, UDP, IGMP, MLD, DHCP, NTP, DNS Encryption TLS 1.2 […]

The post GT-MCX Technical Specifications appeared first on Aiphone.

]]>
Line Drawing

Specifications

Power Source

24V DC, PS-2420UL

Standby 75mA, Maximum 125mA

Wire

2-conductor, PE insulation

CAT5e/6

Wiring Distance

GT-MCX to power supply: 16′

GT-MCX to distribution point: 165′

GT-MCX to GT-VBC 165′
GT-MCX to GT-BC: 165′
GT-MCX to network switch: 330′

Distances are calculated using 20AWG or 18AWG wire.

Protocol

IPv4, IPv6, TCP, UDP, IGMP, MLD, DHCP, NTP, DNS

Encryption

TLS 1.2

Mounting

Din Rail (supplied)

Operating Temperature

32° ~ 104°F (0° ~ 40°C)

Dimensions

8-¼” W x 4-¼” H x 2-⅜” D

Weight

Approx. 0.75 lbs (340g)

The post GT-MCX Technical Specifications appeared first on Aiphone.

]]>
GT-1A Technical Specifications https://www.aiphone.com/kb/gt-1a-spec-sheet/ Sun, 15 Aug 2021 04:18:20 +0000 https://aiphone.local/kb/gt-1a-spec-sheet/ Line Drawing Specifications Power Source 24V DC, supplied from GT-BC Communication Hands-free or Push-to-talk Capacity Maximum 4 GT-1A tenant stations per resident location Wire 2-conductor, PE insulation Wiring Distance GT-1A to distribution point: 980′ GT-1A to doorbell: 33′ GT-1A to emergency alarm switch: 49′ GT-1A to GT-RY: 33′ Mounting Surface wall mount Operating Temperature 32° […]

The post GT-1A Technical Specifications appeared first on Aiphone.

]]>
Line Drawing

Specifications

Power Source

24V DC, supplied from GT-BC

Communication

Hands-free or Push-to-talk

Capacity

Maximum 4 GT-1A tenant stations per resident location

Wire

2-conductor, PE insulation

Wiring Distance

GT-1A to distribution point: 980′

GT-1A to doorbell: 33′

GT-1A to emergency alarm switch: 49′
GT-1A to GT-RY: 33′

Distances are calculated using 20AWG or 18AWG wire.

Mounting

Surface wall mount

Operating Temperature

32° ~ 104°F (0° ~ 40°C)

Dimensions

6-⅞” H x 4-¹⁵⁄₁₆” W x 1-¼” D

Weight

Approx. 0.70 lbs (330g)

The post GT-1A Technical Specifications appeared first on Aiphone.

]]>
GT-1D Technical Specifications https://www.aiphone.com/kb/gt-1d-spec-sheet/ Sun, 15 Aug 2021 04:23:34 +0000 https://aiphone.local/kb/gt-1d-spec-sheet/ Line Drawing Specifications Power Source 24V DC, supplied from GT-BC Communication Duplex Capacity Maximum 4 GT-1A tenant stations per resident location Wire 2-conductor, PE insulation Wiring Distance GT-1D to distribution point: 980′ GT-1D to doorbell: 33′ GT-1D to emergency alarm switch: 49′ GT-1D to GT-RY: 33′ Mounting Surface wall mount Operating Temperature 32° ~ 104°F […]

The post GT-1D Technical Specifications appeared first on Aiphone.

]]>
Line Drawing

Specifications

Power Source

24V DC, supplied from GT-BC

Communication

Duplex

Capacity

Maximum 4 GT-1A tenant stations per resident location

Wire

2-conductor, PE insulation

Wiring Distance

GT-1D to distribution point: 980′

GT-1D to doorbell: 33′

GT-1D to emergency alarm switch: 49′
GT-1D to GT-RY: 33′

Distances are calculated using 20AWG or 18AWG wire.

Mounting

Surface wall mount

Operating Temperature

32° ~ 104°F (0° ~ 40°C)

Dimensions

7-⅞” H x 3-½” W x 2-½” D

Weight

Approx. 0.73 lbs (330g)

The post GT-1D Technical Specifications appeared first on Aiphone.

]]>
Activating a Man Trap With the GT Series https://www.aiphone.com/kb/activating-a-man-trap-with-the-gt-series/ Fri, 03 Sep 2021 03:11:45 +0000 https://aiphone.local/kb/activating-a-man-trap-with-the-gt-series/ See attached PDF.

The post Activating a Man Trap With the GT Series appeared first on Aiphone.

]]>
See attached PDF.

The post Activating a Man Trap With the GT Series appeared first on Aiphone.

]]>
GT Series Remote Programming https://www.aiphone.com/kb/gt-series-remote-programming/ Fri, 03 Sep 2021 03:11:32 +0000 https://aiphone.local/kb/gt-series-remote-programming/ See attached PDF.

The post GT Series Remote Programming appeared first on Aiphone.

]]>
See attached PDF.

The post GT Series Remote Programming appeared first on Aiphone.

]]>
Using Two GT-1C7 Stations per Tenant Location https://www.aiphone.com/kb/using-two-gt-1c7-stations-per-tenant-location/ Fri, 03 Sep 2021 03:12:55 +0000 https://aiphone.local/kb/using-two-gt-1c7-stations-per-tenant-location/ See attached PDF.

The post Using Two GT-1C7 Stations per Tenant Location appeared first on Aiphone.

]]>
See attached PDF.

The post Using Two GT-1C7 Stations per Tenant Location appeared first on Aiphone.

]]>
Unable To Transfer From Entrance or Guard, or Transfer via Setup Tool https://www.aiphone.com/kb/unable-to-transfer-from-entrance-or-guard-or-transfer-via-setup-tool/ Wed, 17 Nov 2021 05:32:56 +0000 https://aiphone.local/kb/unable-to-transfer-from-entrance-or-guard-or-transfer-via-setup-tool/ Summary A number of things can cause this problem such as wrong ID, wrong wiring, no power, and more.   Solution Here are a few solutions to try:   Meter the R1/R2 terminal for voltage.  If you get no voltage, then the R1R2 wire is not connected to the GT-BC, or the GT-BC is not […]

The post Unable To Transfer From Entrance or Guard, or Transfer via Setup Tool appeared first on Aiphone.

]]>
Summary

A number of things can cause this problem such as wrong ID, wrong wiring, no power, and more.

 

Solution

Here are a few solutions to try:

 

  • Meter the R1/R2 terminal for voltage.  If you get no voltage, then the R1R2 wire is not connected to the GT-BC, or the GT-BC is not turned on.
  • Multiple entrance stations or guard stations are all using the same ID.  Adjust the dip switches to ID multiple entrance/guard stations as ID1, ID2, ID3, and so forth. Make sure to cycle power to the GT-BC after making changes. Cycling power on the back of the GT-MKB-N or GT-DMB-N will not work.
  • On an expanded system install, make sure the guard and entrance stations are wired into Common1 and not Sub1a.
  • When using the Setup Tool to upload to the DMB/DB1 or MKB1, if the entrance station’s ID is set as #5, it will fail. Change dip switches to reflect ID1, then cycle power to the GT-BC.
  • If you have a GT-MCX, then the entrance and guard station cannot be ID as #1 as the MCX takes that ID slot. Change the ID of the entrance or guard station as #2, then cycle power to the GT-BC.

The post Unable To Transfer From Entrance or Guard, or Transfer via Setup Tool appeared first on Aiphone.

]]>
An Expanded System Failing To Enter Programming Mode https://www.aiphone.com/kb/an-expanded-system-failing-to-enter-programming-mode/ Wed, 17 Nov 2021 05:38:02 +0000 https://aiphone.local/kb/an-expanded-system-failing-to-enter-programming-mode/ Summary Multiple entrance stations on the system none of which can enter programming mode. None of the entrance stations share the shame dip switch configuration and power to the GT-BC has been cycled.   Solution On an expanded system, the 5 entrances can have their ID set as 1 – 8 and wired into Common1 […]

The post An Expanded System Failing To Enter Programming Mode appeared first on Aiphone.

]]>
Summary

Multiple entrance stations on the system none of which can enter programming mode. None of the entrance stations share the shame dip switch configuration and power to the GT-BC has been cycled.

 

Solution

On an expanded system, the 5 entrances can have their ID set as 1 – 8 and wired into Common1 of the BCXB-N.  If any of them are set as ID #9 or greater and wired into common1 of the BCXB-N, then that entrance station will fail as those ID numbers are reserved for an expanded system, which wires into Common2.

The post An Expanded System Failing To Enter Programming Mode appeared first on Aiphone.

]]>